Measurement of respiratory mechanics using the Puritan-Bennett 7200a ventilator
نویسندگان
چکیده
منابع مشابه
Respiratory mechanics derived from signals in the ventilator circuit.
The aim of this article is to identify and interpret the data provided by modern ventilators that provide the greatest clinical help in evaluating respiratory mechanics during mechanical ventilation. In intensive care, respiratory mechanics can be assessed in dynamic conditions (no flow-interruption) or static conditions (occlusion techniques) to record compliance and resistance and to monitor ...
متن کاملPatient-ventilator asynchronies: may the respiratory mechanics play a role?
INTRODUCTION The mechanisms leading to patient/ventilator asynchrony has never been systematically assessed. We studied the possible association between asynchrony and respiratory mechanics in patients ready to be enrolled for a home non-invasive ventilatory program. Secondarily, we looked for possible differences in the amount of asynchronies between obstructive and restrictive patients and a ...
متن کاملWireless on-demand and networking of Puritan Bennett 840 ventilators for direct data capture.
Manual transcription inaccuracies have been reported to be a frequent occurrence in clinical practice, which has been confirmed in my institution. I explored alternative methods of obtaining data directly from the Puritan Bennett ventilator. The aim of this project was to record all of the ventilator settings and monitored data with wireless technology. I evaluated 2 data-capture methods: on-de...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
BACKGROUND Calculation of total inspiratory resistance (Rtot) for patients on ventilatory support is typically based on measurement of airflow velocity and airway opening pressure during end-inspiratory occlusion by the inspiratory valve in the ventilator. Systematic error is introduced into Rtot measurements because the inspiratory valve closes over a period of time (not instantaneously, so ga...