Measurements of Dose Buildup Factors in Slab Materials for 60Co Isotropic Source
نویسندگان
چکیده
منابع مشابه
Determination of Photon Ambient Dose Buildup Factors for Radiological Applications for Points and Plaque Source Configurations Using MCNP5
Photon ambient dose equivalent buildup factors were calculated for point and plaque isotropic cobalt-60 and cesium-137 radioactive sources irradiating a finite slab shield materials of ordinary concrete, barite concrete, lead, lead glass and water using MCNP5 code. Studied shield thickness ranged from 1 to 15 mean free paths (mfp). A variance reduction technique available in the code was used t...
متن کاملA STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING
The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...
متن کاملMeasurements of exit dose profiles in 60Co beams with a conventional portal film system.
An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured b...
متن کاملChemical Composition Dependence of Exposure Buildup Factors for Some Biological Materials
Exposure buildup factors for some tissues such as bone compact, Muscle striated, orange articulation wax, red articulation wax, nylon, PMMA and paraffin 2 have been computed using the five parameter geometric progression (GP) fitting method in the energy range of 0.01515.0 MeV, up to the penetration of 40 mean free paths (mfp). The variation of exposure buildup factors for all the selected tiss...
متن کاملinfluential factors of customer e-loyalty in iranian e-stores
گسترش سریع تکنولوژی و اینترنت مسیر شرکت ها را به نگهداری وفاداری مشتریان الکترونیکی معطوف کرده است. وفاداری مشتریان یک حوزه بسیار جالب برای شرکت ها می باشد و وفاداری مشتریان تاثیر مستقیم بر درآمد و سودزایی شرکتها دارد. با توجه به اهمیت وفاداری مشتری، ما به جستجوی سه مشکل اصلی تحقیق پرداختیم که آن ها مهمترین موانع برای حفظ حیات کسب و کارهای اینترنتی هستند که عبارت از تعویض های متعدد مشتری، هزینه...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
سال: 1966
ISSN: 0004-7120
DOI: 10.3327/jaesj.8.304