Mechanical performance of ceramic acetabular liners under impact conditions
نویسندگان
چکیده
منابع مشابه
Do thin acetabular shells increase the disassociation risk of ceramic liners?
This study suggests that contemporary modular acetabular shell designs employing ceramic liners deform during implantation where acetabular bed under-reaming is employed. The liner retention strength did not degrade by comparison to non-deformed shells using ASTM static push-out methods. A larger question, however, is the influence of this deformation on liner retention strength over time when ...
متن کاملRetrieval analysis of failed constrained acetabular liners.
Despite the large loads placed upon constrained acetabular liners, little is known of their mechanical performance. We analyzed retrieved liners to determine wear and other damage modes and assess associations between types and severity of damage and clinical, radiographic, and implant variables. Outer rim impingement frequency and severity were higher than that for the inner rim. The 20 degree...
متن کاملThe lubrication performance of the ceramic-on-ceramic hip implant under starved conditions
Lubrication plays an important role in the clinical performance of the ceramic-on-ceramic (CoC) hip implant in terms of reducing wear and avoiding squeaking. All the previous lubrication analyses of CoC hip implants assumed that synovial fluid was sufficiently supplied to the contact area. The aim of this study was to investigate the lubrication performance of the CoC hip implant under starved ...
متن کاملTesting of elastomeric liners used in limb prosthetics: classification of 15 products by mechanical performance.
The mechanical properties of 15 elastomeric liner products used in limb prosthetics were evaluated under compressive, frictional, shear, and tensile loading conditions. All testing was conducted at load levels comparable to interface stress measurements reported on transtibial amputee subjects. For each test configuration, materials were classified into four groups based on the shapes of their ...
متن کاملManual Performance under Cold Conditions
The purpose of this study was to investigate manual performance and thermal responses during low work intensity in persons wearing standard protective clothing in the petroleum industry when they were exposed to a range of temperatures (5, –5, –15 and –25°C) that are relevant to environmental conditions for petroleum industry personnel in northern regions. Twelve men participated in the study. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Arthroplasty
سال: 2003
ISSN: 0883-5403
DOI: 10.1016/s0883-5403(03)00335-8