Mesh Fixation in Laparoscopic Inguinal Hernia Repair: Absorbable vs. Non-Absorbable Tacks

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

laparoscopic tapp inguinal hernia repair: mesh fixation with absorbable tacks, initial experience

conclusions the use of absorbable tacks during tapp confers significant benefit regarding the operating time, however it is a disadvantage due to the cost when compared with fibrin glue. results the group of tacks ‘tapp’ showed good results concerning the level of pain, fatigue and foreign body sensation comparable with those of the historical group. there were significant differences concernin...

متن کامل

Laparoscopic Tapp Inguinal Hernia Repair: Mesh Fixation With Absorbable Tacks, Initial Experience

Background: Preliminary studies have indicated advantages of mesh fixation using fibrin glue in TAPP compared with tack fixation. Objectives: We report the results of a prospective experience in fixing mesh during TAPP with absorbable tacks. Patients and Methods: 50 consecutive men (who had bilateral inguinal hernia) were enrolled and followed up for at least 1 year. The primary measured outcom...

متن کامل

Randomized clinical trial comparing inguinal hernia repair with Lichtenstein technique using non-absorbable or partially absorbable mesh. Preliminary report

INTRODUCTION The Lichtenstein technique is currently considered the "gold standard" of open, anterior inguinal hernia repair. It is not free, however, of adverse effects, which may be caused by the implemented synthetic material. AIM Determination the influence of the mesh employed on treatment results including immediate complications, return to everyday activities, chronic pain occurrence a...

متن کامل

Comparison of partially-absorbable lightweight mesh with heavyweight mesh for inguinal hernia repair: multicenter randomized study

Purpose Prosthetic mesh is widely used for inguinal hernia repair; however, pain and stiffness can develop. This study was a prospective, multicenter, single-blind, randomized trial to assess postoperative pain and quality of life according to mesh type after inguinal hernia repair. Methods Forty-seven patients who underwent Lichtenstein repair for unilateral inguinal hernia with prosthetic m...

متن کامل

Prospective randomized trial of mesh fixation with absorbable versus nonabsorbable tacker in laparoscopic ventral incisional hernia repair.

The aim of this prospective randomized trial was to compare 2 main fixation devices in regard to pain and recurrence in laparoscopic ventral incisional hernia repair (LVIHR). A total of 51 patients were evaluated in this study (n = 25, nonabsorbable tack (NAT) and n = 26, absorbable tack (AT) groups). A visual analogue scale (VAS) was performed on both groups preoperatively and on the postopera...