Metal artifact reduction in x‐ray computed tomography (CT) by constrained optimization
نویسندگان
چکیده
منابع مشابه
Evaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملEdge–Preserving Metal Artifact Reduction in Computed Tomography
Esther Meyer1,2, Rainer Raupach2, Michael Lell3, Bernhard Schmidt2, and Marc Kachelrieß1,4 1Institute of Medical Physics, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany 2Siemens Healthcare, Forchheim, Germany 3Institute of Diagnostic Radiology, Friedrich–Alexander University of Erlangen–Nürnberg (FAU), Erlangen, Germany 4Medical Physics in Radiology, German Cance...
متن کاملSinogram constrained TV-minimization for metal artifact reduction in CT
A new method for reducing metal artifacts in X-ray computed tomography (CT) images is presented. It bases on the solution of a convex optimization problem with inequality constraints on the sinogram, and total variation regularization for the reconstructed image. The Chambolle-Pock algorithm is used to numerically solve the discretized version of the optimization problem. As proof of concept we...
متن کاملFrequency split metal artifact reduction (FSMAR) in computed tomography.
PURPOSE The problem of metal artifact reduction (MAR) is almost as old as the clinical use of computed tomography itself. When metal implants are present in the field of measurement, severe artifacts degrade the image quality and the diagnostic value of CT images. Up to now, no generally accepted solution to this issue has been found. In this work, a method based on a new MAR concept is present...
متن کاملMetal Artifact Reduction from Computed Tomography (CT) Images using Directional Restoration Filter
Computed tomography angiography (CTA) is a stabilized tool for vessel imaging in the medical image processing field. High-intense structures in the contrast image can seriously hamper luminal visualization. Metal artifacts are an extensive problem in computed tomography (CT) images. We proposed directional restoration filtering process with Fuzzy logic in order to reduce metal artifact from CT ...