Misidentification ofBrucella melitensisasBergeyella zoohelcumby MicroScan WalkAway®: A Case Report

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Misidentification of Brucella melitensis as Bergeyella zoohelcum by MicroScan WalkAway®: a case report.

OBJECTIVE To describe the misidentification of Brucella melitensis as Bergeyella zoohelcum by MicroScan WalkAway®, a commonly used bacterial identification system. CLINICAL PRESENTATION AND INTERVENTION A 35-year-old man was admitted to the Intensive Care Unit with sepsis syndrome. Three sets of aerobic blood culture samples were positive after 48 h of incubation. The isolated organism was id...

متن کامل

Identification of Hafnia alvei with the MicroScan WalkAway system.

Hafnia alvei is a gram-negative facultatively anaerobic bacillus that belongs to the family Enterobacteriaceae. This organism is a causative agent of intestinal disorders and is found in different environments. H. alvei has received increased clinical attention as a cause of different infections in humans. This study was performed to compare the MicroScan WalkAway automated identification syste...

متن کامل

Detecting imipenem resistance in Acinetobacter baumannii by automated systems (BD Phoenix, Microscan WalkAway, Vitek 2); high error rates with Microscan WalkAway

BACKGROUND Increasing reports of carbapenem resistant Acinetobacter baumannii infections are of serious concern. Reliable susceptibility testing results remains a critical issue for the clinical outcome. Automated systems are increasingly used for species identification and susceptibility testing. This study was organized to evaluate the accuracies of three widely used automated susceptibility ...

متن کامل

Multilaboratory study of the Biomic automated well-reading instrument versus MicroScan WalkAway for reading MicroScan antimicrobial susceptibility and identification panels.

This study compared the Biomic automated well reader results to the MicroScan WalkAway results for reading MicroScan antimicrobial susceptibility and identification panels at four different sites. Routine fresh clinical isolates and quality control (QC) organisms were tested at each study site. A total of 46,176 MicroScan panel drug-organism combinations were read. The Biomic category agreement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Principles and Practice

سال: 2012

ISSN: 1423-0151,1011-7571

DOI: 10.1159/000338391