Modelling short-circuit current of a 21 MVA HTS superconducting transformer
نویسندگان
چکیده
منابع مشابه
Decreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کاملDevelopment of HTS Transformers and a 10 kVA HTS Transformer Prototype Design
⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer...
متن کاملEddy Current Losses in Transformer Windings and Circuit Wiring
Skin Effect Figure 1 shows the magnetic field (flux lines) in and around a conductor carrying dc or low frequency current I. The field is radially symmetrical, as shown, only if the return current with its associated field is at a great distance. At low frequency, the energy in the magnetic field is trivial compared to the energy loss in the resistance of the wire. Hence the current Introductio...
متن کاملGeneration of highly stable DC current by using a superconducting transformer
The purpose of this study is to generate a highly stable DC current by using a superconducting transformer. For the first trial stage, a 100 A class superconducting transformer was designed and fabricated for operation at the temperature of liquid nitrogen. The secondary coil of the transformer was wound with a superconducting Bi-2223 tape, and the turn ratio of the primary and secondary windin...
متن کاملSolver for a Magnetic Equivalent Circuit and Modeling the Inrush Current of a 3-Phase Transformer
Knowledge about the magnetic quantities in a magnetic circuit is always of great interest. On the one hand, this information is needed for the simulation of a transformer. On the other hand, parameter studies are more reliable, if the magnetic quantities are derived from a well established model. One possibility to model the 3-phase transformer is by using a magnetic equivalent circuit (MEC). T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2021
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1782/1/012036