Modified R–L model‐based protection for VSC‐DC distribution lines
نویسندگان
چکیده
منابع مشابه
Lightning Protection of Overhead Power Distribution Lines
Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...
متن کاملAutomated Production of Information Models for Use in Modelbased Diagnosis
The most difficult part of system maintenance is diagnosing failures. System expertise is needed, but manuals cannot cover all the unique situations and in-house experts are difficult to retain because of today’s budgets. The resulting “expertise gap” has led to the development of “intelligent” diagnostic aids to compensate for the missing expertise. The first computer-assisted diagnostic aids ...
متن کاملTemplate- and modelbased code generation for MDA-Tools
The Model Driven Architecture (MDA) proposes model transformations to obtain an executable model from a platform independent model. Unless one uses an interpreter the common executable model of an application is specified in some programming language. To obtain such an implementation of a model automatically is the task of code generation in MDA-Tools. In this paper we present a modelbased appr...
متن کاملPractical Key Distribution Schemes for Channel Protection
This paper presents three key distribution schemes for channel protection. With the proposed schemes, encryption keys of the ordered programs can be distributed to the authorized subscribers efficiently and securely. In these schemes, for key updates, at most two messages are transmitted and simpler computation functions, including one-way hash function and XOR operation, are used to reduce the...
متن کاملSimulation of Combined Shield Wire and MOV protection on Distribution Lines in Severe Lightning Areas
This paper presents the protective effects of shield wire coupled with Metal Oxide Varistor (MOV) arresters in a distribution network located in a severe lightning area. The presented test case is the IEEE 34-node radial distribution test feeder injected with multiple lightning strokes and simulated with the Alternative Transients Program/ Electromagnetic Transients program (ATP/EMTP). The resp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Engineering
سال: 2017
ISSN: 2051-3305,2051-3305
DOI: 10.1049/joe.2017.0650