Moisture diffusion measurement and evaluation for porous membranes used in enthalpy exchangers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Semi-Cylindrical Capacitive Sensor Used for Soil Moisture Measurement

Differing from the structure of traditional parallel plate capacitive sensor a semi cylindrical capacitive sensor has been introduced in this present work to measure the soil moisture conveniently. Here, the numerical analysis method to evaluate the capacitance from the semi-cylindrical capacitive sensor is analyzed and discussed. The changes of capacitance with the variation of soil moisture o...

متن کامل

Heat-and-moisture exchangers used with biweekly circuit tubing changes: effect on costs and pneumonia rates.

In 1991, heat-and-moisture exchangers were introduced with biweekly ventilator circuit tubing changes, resulting in elimination of multiple pieces of respiratory equipment and reduced labor costs. The annual savings were $157,000, totalling $1.5 million since the onset of the program. There have been no increases in rates of ventilator-associated pneumonia.

متن کامل

In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients.

BACKGROUND Heat and moisture exchangers (HMEs) are commonly used in chronically tracheostomized spontaneously breathing patients, to condition inhaled air, maintain lower airway function, and minimize the viscosity of secretions. Supplemental oxygen (O2) can be added to most HMEs designed for spontaneously breathing tracheostomized patients. We tested the efficiency of 7 HMEs designed for spont...

متن کامل

Filtration, Diffusion, and Molecular Sieving through Porous Cellulose Membranes

1. A study has been made of the diffusion and filtration of a graded series of molecules (including tritium-labelled water, urea, glucose, antipyrine, sucrose, raffinose, and hemoglobin) in aqueous solution through porous cellulose membranes of three degrees of porosity. 2. Experimental results were in close agreement with predictions based on the membrane pore theory of Pappenheimer et al. (1,...

متن کامل

Diffusion Mechanism and Quantitative Measurement of Moisture Transport in Porous Silica Gel Filter Using Dynamic Neutron Radiography Technique

Neutron radiography (NR) can investigate the diffusion mechanisms of moisture transport within the silica gel material. Dynamic neutron radiography (DNR) possesses the possibility to investigate the moisture profile inside the silica gel filter. The technique explained the relationship between moisture movement and time. This study investigated the diffusion mechanisms (absorption and infiltrat...