Monitoring lung compliance and end-tidal oxygen content for the detection of venous air embolism

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring lung compliance and end-tidal oxygen content for the detection of venous air embolism.

Venous air embolism (VAE) is a recognized complication of surgery performed with the patient in the sitting position, but it occurs also during other operations. We report two cases of VAE, associated with a notable decrease in dynamic lung compliance, detected by side-stream spirometry. Based on these cases, an experiment with 10 pigs was designed to evaluate the usefulness of side-stream spir...

متن کامل

Comparison of external lung monitoring with end-tidal air detection using the 133xenon inhalation method.

When the 133Xe inhalation method is employed for measuring regional cerebral blood flow, the arterial 133Xe concentration is usually approximated by the end-tidal air concentration. However, this approximation may be invalid in the presence of certain lung pathologies or when the breathing pattern is irregular. Jaggi and Obrist, using an intravenous injection of 133Xe, suggested that the counts...

متن کامل

Comparison of External Lung Monitoring With End-Tidal Air Detection Using the Xenon Inhalation Method

When the Xe inhalation method is employed for measuring regional cerebral blood flow, the arterial Xe concentration is usually approximated by the end-tidal air concentration. However, this approximation may be invalid in the presence of certain lung pathologies or when the breathing pattern is irregular. Jaggi and Obrist, using an intravenous injection of Xe, suggested that the counts detected...

متن کامل

Successful late treatment of venous air embolism with hyperbaric oxygen.

A case of haemodialysis-associated venous air embolism is described. The patient commenced hyperbaric oxygen therapy 21 hours after the event when, despite appearing decerebrate, he made a complete recovery. This case underlines the importance of all clinicians being aware of those centres with facilities for hyperbaric therapy and the need to refer all patients with cerebral air embolism even ...

متن کامل

. Venous Air Embolism During Operative

C6mplications of hysteroscopy occur more frequently in operative than in diagnostic cases. Problems related to‘uterine distension are common, usually preventable, and potentially extremely serious. Perforation of the LFXIS may occur during hysteroscopy but do not always cause significant problems. In procedures of high risk i,r perforation the use of mechanical energy is safer than either laser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 1995

ISSN: 0007-0912

DOI: 10.1093/bja/75.4.447