Monte Carlo Calculations: Thermodynamic Functions in Zeolites II. Adsorption of Benzene on Silicalite
نویسندگان
چکیده
منابع مشابه
Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...
متن کاملMonte Carlo calculations
A Monte Carlo simulation using the PRESTA version of the EGS4 code has been employed as an investigative tool to calculate the absorbed dose in water close to 192Ir wire implants. It has been shown that a treatment planning system, such as GE Target II, using the Sievert integral and the Meisberger polynomial is only able to reproduce the Monte Carlo results at radial distances of 1 mm and fart...
متن کاملBinding of hydrogen on benzene, coronene, and graphene from quantum Monte Carlo calculations.
Quantum Monte Carlo calculations with the diffusion Monte Carlo (DMC) method have been used to compute the binding energy curves of hydrogen on benzene, coronene, and graphene. The DMC results on benzene agree with both Møller-Plessett second order perturbation theory (MP2) and coupled cluster with singles, doubles, and perturbative triples [CCSD(T)] calculations, giving an adsorption energy of...
متن کاملBenchmark quantum Monte Carlo calculations
Fixed node diffusion Monte Carlo !FN-DMC" atomization energies are calculated for a benchmark set of 55 molecules. Using single determinant trial wave functions, comparison with experiment yields an average absolute deviation of 2.9 kcal/mol, placing this simplest form of FN-DMC roughly at the same level of accuracy as the CCSD!T"/aug-cc-pVQZ method. However, unlike perturbative wave function e...
متن کاملradial dose functions of gzp6 intracavitary brachytherapy 60co sources: treatment planning system versus monte carlo calculations
background: the monte carlo (mc) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (tps) calculations. materials and methods: three 60co sources of gzp6 brachytherapy unit were simulated using mcnp4c mc code. the radial dose functions were calculated by mc method and gzp6 tps and were compared. results: there was a go...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Adsorption Science & Technology
سال: 1988
ISSN: 0263-6174,2048-4038
DOI: 10.1177/026361748800500302