Multiplexed Readout of MMC Detector Arrays Using Non-hysteretic rf-SQUIDs
نویسندگان
چکیده
منابع مشابه
High temperature RF SQUIDs for biomedical applications.
We have been investigating the feasibility of radio-frequency RF, low-noise superconducting quantum interference device (SQUID) magnetometers and gradiometers operating in liquid nitrogen at 77 K. Using flux-focusing structures fabricated from epitaxial YBa2Cu3O7-chi films, we have attained a magnetic field resolution for a magnetometer of better than 200 fT Hz-1/2 at less than 1 Hz, i.e. over ...
متن کاملFrequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements.
A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system wh...
متن کاملMultiplexed dispersive readout of superconducting phase qubits
Yu Chen, D. Sank, P. O’Malley, T. White, R. Barends, B. Chiaro, J. Kelly, E. Lucero, M. Mariantoni, A. Megrant, C. Neill, A. Vainsencher, J. Wenner, Y. Yin, A. N. Cleland, and John M. Martinis Department of Physics, University of California, Santa Barbara, California 93106, USA California NanoSystems Institute, University of California, Santa Barbara, California 93106, USA Department of Materia...
متن کاملMicro-SQUIDs based on MgB2 nano-bridges for NEMS readout
We show the results obtained from the fabrication and characterisation of MgB2 loops with two nano-bridges as superconducting weak links. These ring structures are made to operate as superconducting quantum interference devices and are investigated as readout system for cryogenics NEMS resonators. The nano-constrictions are fabricated by EBL and ion beam milling. The SQUIDs are characterised at...
متن کاملVery Low Noise Multiplexing with SQUIDs and SiGe Heterojunction Bipolar Transistors for Readout of Large Superconducting Bolometer Arrays
This paper presents an ultra low noise instrumentation based on a standard BiCMOS SiGe 0.35 μm ASIC operating at cryogenic temperatures. The main functions of the electronic circuit are the readout and the multiplexing of SQUIDs/TES. We report the cryogenic operation of the ASIC dedicated to the readout of a 2x4 pixel demonstrator array. We particularly emphasize on the development and the test...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Low Temperature Physics
سال: 2013
ISSN: 0022-2291,1573-7357
DOI: 10.1007/s10909-013-1041-0