Multivariate optimization of ultrasound-assisted extraction using Doehlert matrix for simultaneous determination of Fe and Ni in vegetable oils by high-resolution continuum source graphite furnace atomic absorption spectrometry
نویسندگان
چکیده
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملDetermination of Pb (Lead), Cd (Cadmium), Cr (Chromium), Cu (Copper), and Ni (Nickel) in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry.
The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory...
متن کاملDevelopment of ultrasound-assisted emulsification microextraction for the determination of trace zinc and copper by flame atomic absorption spectrometry
In this work, we developed a method based on ultrasound-assisted emulsification microextraction (USAEME) for the determination of zinc and copper by flame atomic absorption spectrometry (FAAS). The method is based on the use of the organic solvent carbon tetrachloride (CCl4) as an extraction solvent. In order to obtain a high enrichment factor, the effect of different parameters affecting the c...
متن کاملMultivariate Optimization in the Direct Determination of Antimony and Chromium in Serum Samples by Graphite Furnace Atomic Absorption Spectrometry
Methods for direct determination of antimony and chromium in human serum by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) were proposed in this work. The samples were diluted in 1:1 with nitric acid 1% v/v and Triton® X-100 0.1% v/v. The optimization of the instrumental conditions was done using a multivariate approach. A factorial design (2) was employed to investigate the tendency ...
متن کاملDetermination of Lead in Eye Shadow and Blush by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Employing Direct Solid Sampling
A espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) é proposta para determinar Pb em sombra de olho e blush empregando a análise direta de sólidos. O emprego da mistura de modificadores químicos Pd(NO3)2 + Mg(NO3)2 possibilitou a calibração aquosa de 0,25 a 2,5 ng Pb (r = 0,998). O desempenho do método proposto foi avaliado por meio da an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Food Chemistry
سال: 2019
ISSN: 0308-8146
DOI: 10.1016/j.foodchem.2018.01.112