Negative Sequence Voltage Magnitude based Unsynchronized Fault Location on Three Terminal Lines
نویسندگان
چکیده
منابع مشابه
Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages
The increased accuracy into the fault’s detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids’ lines are presented. The double-end synchronized data algorithm...
متن کاملA Neuro-fuzzy Approach for the Fault Location Estimation of Unsynchronized Two-terminal Transmission Lines
Overhead transmission line is an element of electrical power systems that are most frequently experienced short circuit faults compared to other power system elements. Short circuit faults on overhead transmission line cause a relatively large current and therefore can damage mechanically the electrical equipment connected to the system. The protection system is essentially needed in this situa...
متن کاملInternal Fault Detection, Location, and Classification in Stator Winding of the Synchronous Generators Based on the Terminal Voltage Waveform
In this paper, a novel method is presented for detection and classification of the faultyphase/region in the stator winding of synchronous generators on the basis of the resulting harmoniccomponents that appear in the terminal voltage waveforms. Analytical results obtained through DecisionTree (DT) show that the internal faults are not only detectable but also they can be classified andthe rela...
متن کاملOne Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage
This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...
متن کاملFault Location on Compensated Transmission Lines without Current Measurement
This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...