Noise Spectra for Monolithic Detector Arrays
نویسندگان
چکیده
منابع مشابه
Design of a Lock-in Amplifier For Terahertz Detector And Imager Arrays on Monolithic CMOS
This work describes the design and integration of a lock-in amplifier with a terahertz detector array. Research in the terahertz region, which lies between the microwave and infrared portion of the electromagnetic spectrum, has been on the rise due to its potential applications as a biologically-safe replacement for X-Ray imaging and other non-invasive applications such as spectroscopy. Cryogen...
متن کاملInfrared Detector Arrays for Astronomy
Use of infrared detector arrays in astronomy began roughly 20 years ago, and our detection capabilities in parts of this spectral range have doubled about every seven months since then. A variety of approaches are now used for detector arrays operating from 1 μm to 1 mm and beyond. They include direct hybrid arrays of InSb and HgCdTe photodiodes that operate from 0.6μm to 5μm, and of Si:As impu...
متن کاملA monolithic evanescent field spore detector
We demonstrate a monolithically integrated particle sensor based on evanescent field scattering, well suited for use with affinity assays for pathogen recognition. Single micron sized particles may be detected, representative of spores and small bacteria. ©2004 Optical Society of America OCIS codes: (250.5300) Photonic integrated circuits; (140.5960) Semiconductor lasers
متن کاملMonolithic CMOS Pixel Detector for ILC Vertex Detection
Studies in the U.S., Europe, and Asia, have demonstrated the power of a pixel vertex detector in experiments at a future high energy linear collider. Silicon CCDs (Charged Coupled Devices) [1] seemed like the vertex detector sensors of choice for the International Linear Collider (ILC) until the accelerator technology decision. With the choice of a cold TESLAlike superconducting technology for ...
متن کاملLarge-Area APDs and Monolithic APD Arrays
In this paper, development of large-area planar avalanche photodiodes (APDs) and monolithic APD arrays for X-ray and scintillation detection is discussed. Single APDs with areas as large as 10 cm have been fabricated and tested with a CsI(Tl) scintillator (3.8 cm diameter, 2.5 cm height). The resolution of the 662-keV photopeak has been measured to be 9% (FWHM). The X-ray detection performance,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 1978
ISSN: 0018-9456