Nonlinear $C_{oss}-V_{DS}$ Profile Based ZVS Range Calculation for Dual Active Bridge Converters

نویسندگان

چکیده

Generally, power electronic converters are designed to obtain the highest efficiency at rated while they most often operated under partial loading conditions. For dual active bridge converters, zero-voltage-switching (ZVS) conditions can be impaired light load situations. While depending ZVS operation has been introduced by prior-art approaches, nonlinear characteristic of output capacitance in a device is not considered and its effect on operating boundaries neglected. In this letter, based practical switching transients, an improved method calculating range introduced. By taking into account nonlinearity capacitance, developed from detailed analysis real transients. A 2.5-kW prototype built, comprehensive comparison with approaches conducted validate accuracy proposed method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Backflow Power Optimization Control for Dual Active Bridge DC-DC Converters

Abstract: This paper proposes optimized control methods for global minimum backflow power based on a triple-phase-shift (TPS) control strategy. Three global optimized methods are derived to minimize the backflow power on the primary side, on the secondary side and on both sides, respectively. Backflow power transmission is just a portion of non-active power transmission in a dual active bridge ...

متن کامل

Hybrid Modulation of Bidirectional Three-Phase Dual-Active-Bridge DC Converters for Electric Vehicles

Bidirectional power converters for electric vehicles (EVs) have received much attention recently, due to either grid-supporting requirements or emergent power supplies. This paper proposes a hybrid modulation of the three-phase dual-active bridge (3ΦDAB) converter for EV charging systems. The designed hybrid modulation allows the converter to switch its modulation between phase-shifted and trap...

متن کامل

Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype

One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...

متن کامل

Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype

One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Power Electronics

سال: 2021

ISSN: ['1941-0107', '0885-8993']

DOI: https://doi.org/10.1109/tpel.2020.3003248