OC-0085: Improving CT calibration for proton range prediction by dual-energy CT based patient-cohort analysis
نویسندگان
چکیده
منابع مشابه
A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملa novel dual energy ct-based attenuation correction method in pet/ct systems: a phantom study
in present pet/ct scanners, pet attenuation correction is performed by relying on the information given by ct scan. in the ct-based attenuation correction methods, dual-energy technique (dect) is the most accurate approach, which has been limited due to the increasing patient dose. in this feasibility study, we have introduced a new method that can implement dual-energy technique with only a si...
متن کاملDual-Energy CT in Neuroimaging
Image contrast in CT is mostly dependent on elements with high atomic weight, such as calcium, iron, and iodine The concentrations of these elements can be calculated from dual-energy x-ray data based on their characteristic attenuation patterns Dual-energy CT may can be helpful in neuroimaging to: Differentiate between hemorrhage and iodinated contrast agents in brain parenchyma Improve CT ang...
متن کاملNonuniqueness in dual-energy CT.
PURPOSE The goal is to determine whether dual-energy computed tomography (CT) leads to a unique reconstruction using two basis materials. METHODS The beam-hardening equation is simplified to the single-voxel case. The simplified equation is rewritten to show that the solution can be considered to be linear operations in a vector space followed by a measurement model which is the sum of the ex...
متن کاملDual Energy CT - Analysis of Kidney Stones for Specific PatientTreatment
Regional brain atrophy is a typical structural symptom of Alzheimer's disease (AD). Magnetic resonance imaging (MRl) scans capture brain structure with high resolution and are often processed with automated segmentation and parcellation algorithm like Freesurfer to generate regional measures, llke cortical volume, cortical thickness and surface area, which are widely used as inputs in classific...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2018
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(18)30395-5