OC-0413 MR-derived signals for respiratory motion models evaluated using sagittal and coronal datasets
نویسندگان
چکیده
منابع مشابه
Registration of temporal sequences of coronal and sagittal MR images through respiratory patterns
This work discusses the determination of the breathing patterns in time sequence of images obtained frommagnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real move...
متن کاملPET motion correction using MR-derived motion parameters
Medical Imaging Research Center, Department of Nuclear Medicine, KU Leuven, Belgium With the improving resolution of modern PET scanners, any slight motion during the scan can cause significant blurring and loss of resolution. MRI scanners have the capacity to perform quick successive scans and thus provide a means to track motion during a scan. Hence, with the advent of simultaneous PET-MR sca...
متن کاملJoint PET-MR respiratory motion models for clinical PET motion correction
Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET da...
متن کاملNormal sagittal and coronal suture widths by using CT imaging.
BACKGROUND AND PURPOSE Pediatric cranial sutures are often evaluated for abnormal diastasis upon presentation to the emergency department after trauma or during a neurologic consultation; however, few normative data for CT measurements exist. This study establishes normal means for the sagittal and coronal suture widths during the first year of life by using CT. MATERIALS AND METHODS The sagi...
متن کاملJoint PET-MR respiratory motion models for clinical PET motion correction.
Patient motion due to respiration can lead to artefacts and blurring in positron emission tomography (PET) images, in addition to quantification errors. The integration of PET with magnetic resonance (MR) imaging in PET-MR scanners provides complementary clinical information, and allows the use of high spatial resolution and high contrast MR images to monitor and correct motion-corrupted PET da...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2019
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(19)30833-3