OC-0567: In vivo dosimetry in Intra-Operative Partial Breast Irradiations
نویسندگان
چکیده
منابع مشابه
EPID in vivo Dosimetry
Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...
متن کاملSkin in vivo Dosimetry in Radiotherapy
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
متن کاملBreast in vivo dosimetry by EPID
An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two-dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time. In the present paper, a new procedure has been proposed to improve the EPID in vivo dosimetry accuracy by taking into account the patient setup ...
متن کاملintra-operative assessment of sentinel lymph nodes in breast cancer
lymph node status remains an important prognostic indicator for survival in breast cancer. sentinel lymph node biopsy has become the standard method of assessment of clinically node negative breast cancers. economic implications as well as patient related factors have lead to the development a number of intra-operative techniques. review of the emerging trends in the last 4 years show that alth...
متن کاملOptimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations
The methodology of cytogenetic triage can be improved by optimizing a schedule of microscopy for different exposure scenarios. Chromosome aberrations were quantified by microscopy in human blood lymphocytes irradiated in vitro to ~2, 4, and 12 Gy acute 60Co γ-rays mixed with the unirradiated blood simulating 10%, 50%, 90%, and 100% exposure and in along with a sample from a homogeneous exposure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2015
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(15)40561-4