OPTIMUM SEISMIC RESPONSE CONTROL OF STRUCTURAL SYSTEMS USING MAXWELL-TYPE NON-LINEAR VISCOUS DAMPER
نویسندگان
چکیده
منابع مشابه
Study and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...
متن کاملSeismic Response of Building Structures with Sliding Non-structural Elements
Interaction between a structure under base excitation and heavy non-structural elements that it supports is significant in the seismic analysis and design of the structure. Heavy non-structural elements may slide/rock under base excitation, and this dynamic action affects the seismic behavior of the supporting structure. Hence, in this study, a numerical model was presented to describe the seis...
متن کاملThe Effect of Tuned Mass Damper on Seismic Response of Building Frames with Uncertain Structural Characteristics
Tuned mass dampers (TMDs) could be used to absorb the input energy of the applied load, and reduce the response of the building frames. However, the effectiveness of TMD in reducing the response of the building frames could be affected by inherited uncertainties in the structural characteristics of the frames. In this study, in order to investigate the probabilistic response of steel moment-res...
متن کاملa new type-ii fuzzy logic based controller for non-linear dynamical systems with application to 3-psp parallel robot
abstract type-ii fuzzy logic has shown its superiority over traditional fuzzy logic when dealing with uncertainty. type-ii fuzzy logic controllers are however newer and more promising approaches that have been recently applied to various fields due to their significant contribution especially when the noise (as an important instance of uncertainty) emerges. during the design of type- i fuz...
15 صفحه اولEvaluation of Seismic Performance and Effectiveness of Multiple Slim-Type Damper System for Seismic Response Control of Building Structures
This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2001
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.66.83_1