Current Directional Protection of Series Compensated Line Using Intelligent Classifier
Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...
متن کاملFault Location on Compensated Transmission Lines without Current Measurement
This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...
متن کاملMicromachined Hydraulic Astable Multivibrator
1 Abstract The paper presents a hydraulic astable multivibrator system. The system consists of hydraulic resistors, hydraulic capacitors and hydraulic pressure controlled valves. The system is designed, realised and tested. The measured system behaviour agrees well with the model simulations. The free running frequency of the multivibrator is 0.18 Hz and the output pressure swing is 90% of the ...
متن کاملOverload Control in Smart Transformer-Fed Grid
Renewable energy resources and new loads—such as electric vehicles—challenge grid management. Among several scenarios, the smart transformer represents a solution for simultaneously managing lowand medium-voltage grids, providing ancillary services to the distribution grid. However, unlike conventional transformers, the smart transformer has a very limited overload capability, because the junct...
متن کاملA Short-Current Control Method for Constant Frequency Current-Fed Wireless Power Transfer Systems
Abstract: Frequency drift is a serious problem in Current-Fed Wireless Power Transfer (WPT) systems. When the operating frequency is drifting from the inherent Zero Voltage Switching (ZVS) frequency of resonant network, large short currents will appear and damage the switches. In this paper, an inductance-dampening method is proposed to inhibit short currents and achieve constant-frequency oper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Magnetics Society of Japan
سال: 1997
ISSN: 0285-0192