Ozone profile retrievals from the Ozone Monitoring Instrument

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of operational ozone profiles from the Ozone Monitoring Instrument

[1] In this paper we present the validation results of the operational vertical ozone profiles retrieved from the nadir observations by the Ozone Monitoring Instrument (OMI) aboard the NASA Earth Observing System (EOS) Aura platform. The operational ozone profile retrieval algorithm was developed at the Royal Netherlands Meteorological Institute and the OMI mission data has been processed and m...

متن کامل

Impact of using different ozone cross sections on ozone profile retrievals from Global Ozone Monitoring Experiment (GOME) ultraviolet measurements

We investigate the effect of using three different cross section data sets on ozone profile retrievals from Global Ozone Monitoring Experiment (GOME) ultraviolet measurements (289–307 nm, 326–337 nm). These include Bass-Paur, Brion, and GOME flight model cross sections (references below). Using different cross sections can significantly affect the retrievals, by up to 12 Dobson Units (DU, 1 DU=...

متن کامل

Glyoxal retrieval from the Ozone Monitoring Instrument

We present an algorithm for the retrieval of glyoxal from backscattered solar radiation, and apply it to spectra measured by the Ozone Monitoring Instrument (OMI). The algorithm is based on direct spectrum fitting, and adopts a two-step fitting routine to account for liquid water absorption. Previous studies have shown that glyoxal retrieval algorithms are highly sensitive to the position of th...

متن کامل

So2 Data from the Ozone Monitoring Instrument

We discuss collection 2 SO2 data from the DutchFinnish Ozone Monitoring Instrument (OMI) on board NASA EOS/Aura spacecraft and show examples of detected volcanic and anthropogenic SO2 emissions. Quantification of anthropogenic SO2 emissions requires collection 3 reprocessing available in the fall 2007.

متن کامل

Validation of SO2 retrievals from the Ozone Monitoring Instrument over NE China

[1] The Dutch-Finnish Ozone Monitoring Instrument (OMI) launched on the NASA Aura satellite in July 2004 offers unprecedented spatial resolution, coupled with contiguous daily global coverage, for space-based UV measurements of sulfur dioxide (SO2). We present a first validation of the OMI SO2 data with in situ aircraft measurements in NE China in April 2005. The study demonstrates that OMI can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Atmospheric Chemistry and Physics

سال: 2010

ISSN: 1680-7324

DOI: 10.5194/acp-10-2521-2010