Parameters affecting temporal resolution of Time Resolved Integrative Optical Neutron Detector (TRION)

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Femtosecond time-resolved optical and Raman spectroscopy of photoinduced spin crossover: temporal resolution of low-to-high spin optical switching.

A combination of femtosecond electronic absorption and stimulated Raman spectroscopies has been employed to determine the kinetics associated with low-spin to high-spin conversion following charge-transfer excitation of a FeII spin-crossover system in solution. A time constant of tau = 190 +/- 50 fs for the formation of the 5T2 ligand-field state was assigned based on the establishment of two i...

متن کامل

An Improvement in Temporal Resolution of Seismic Data Using Logarithmic Time-frequency Transform Method

The improvement in the temporal resolution of seismic data is a critical issue in hydrocarbon exploration. It is important for obtaining more detailed structural and stratigraphic information. Many methods have been introduced to improve the vertical resolution of reflection seismic data. Each method has advantages and disadvantages which are due to the assumptions and theories governing their ...

متن کامل

Prototype developments for a high-resolution neutron detector at RB

A detector for momentum measurements of highenergy neutrons in the energy range 200 MeV to 1000 MeV is being developed for the RB experiment at FAIR. The detection principle is based on a combination of converter material and subsequent detection of charged particles from reactions in the converter material. Multigap Resistive-Plate Chambers (MRPC) are used for the detection of charged particle...

متن کامل

Time-resolved optical spectroscopy of wood.

We have proposed and experimentally demonstrated that picosecond time-resolved optical spectroscopy in the visible/near-infrared (NIR) region (700-1040 nm) is a useful technique for noninvasive characterization of wood. This technique has been demonstrated on both softwood and hardwood samples treated in different ways simulating the aging process suffered by waterlogged woods. In all the cases...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2013

ISSN: 1748-0221

DOI: 10.1088/1748-0221/8/11/p11012