Is the Parker Flex-Tip tube really superior to the standard tube for fiberoptic orotracheal intubation?

To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the stand...

متن کامل

Is the Parker Flex-Tip Tube Really Superior to the Standard Tube for Fiberoptic Orotracheal Intubation?

To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the stand...

متن کامل

Ease of intubation with the Parker Flex-Tip or a standard Mallinckrodt endotracheal tube using a video laryngoscope (GlideScope).

Two endotracheal tubes (ETTs) are available for use in operative suites for intubation: the Parker Flex-Tip (PFT, Parker Medical) and the standard Mallinckrodt (Covidien). To the authors' knowledge, no study has compared these 2 ETTs with each other when the anesthesia provider uses the GlideScope video laryngoscope (Verathon) for intubation. The purpose of the study was to determine if there a...

متن کامل

Pentax-AWS videolaryngoscope for awake nasal intubation in patients with unstable necks.

In patients with unstable necks and at risk of pulmonary aspiration, awake fibreoptic intubation is often appropriate. However, stabilization of the neck can make fibreoptic intubation more difficult. I report the use of awake nasal intubation using the Pentax-Aiway Scope (AWS) in three patients with restricted neck movement, in whom awake fibreoptic intubation had failed. Case 1: a 59-yr-old m...

متن کامل

A comparison of the force applied on oral structures during intubation attempts between the Pentax-AWS airwayscope and the Macintosh laryngoscope: a high-fidelity simulator-based study

OBJECTIVE We sought to determine whether the use of Pentax-AWS Airwayscope (AWS) applied less force on oral structures during intubation attempts than a conventional direct laryngoscope (DL). DESIGN Prospective cross-over study. PARTICIPANTS A total of 37 physicians (9 transitional-year residents, 20 emergency medicine residents and 8 emergency physicians) were enrolled. INTERVENTIONS We ...