Patterned Electrode-Based Amperometric Gas Sensor for Direct Nitric Oxide Detection within Microfluidic Devices
نویسندگان
چکیده
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملEffect of Electrode Configuration on Nitric Oxide Gas Sensor Behavior
The influence of electrode configuration on the impedancemetric response of nitric oxide (NO) gas sensors was investigated for solid electrochemical cells [Au/yttria-stabilized zirconia (YSZ)/Au)]. Fabrication of the sensors was carried out at 1050 °C in order to establish a porous YSZ electrolyte that enabled gas diffusion. Two electrode configurations were studied where Au wire electrodes wer...
متن کاملA Two Electrode Electrochemical Amperometric Sensor for NO2 Detection. A.Fort,
In this work a new and simple two electrode amperometric sensor for NO2 detection is described. The sensor consists of a Nafion® proton exchange membrane (PEM), a Graphite working electrode, and a NiO counter electrode. The developed sensor presents a good sensitivity to NO2 and very small cross sensitivity to CO and O2. A dedicated measurement system was developed, and a measurement protocol w...
متن کاملNovel Measuring Method for Detection of Propene Using Zirconia-Based Amperometric Sensor with Oxide-Based Sensing Electrode
An amperometric sensor based on yttria-stabilized zirconia (YSZ) and an oxidebased sensing electrode (SE) was examined for the detection of propene. Among the various oxide-based SEs tested, ZnO (+8.5 wt.% Pt) was found to give good sensitivity and selectivity to C3H6 at 600°C. A novel measuring method named “pulsed-potential method” was adopted here to obtain improved sensing characteristics. ...
متن کاملQuantum cascade laser-based sensor system for nitric oxide detection
Sensitive detection of nitric oxide (NO) at ppbv concentration levels has an important impact in diverse fields of applications including environmental monitoring, industrial process control and medical diagnostics. For example, NO can be used as a biomarker of asthma and inflammatory lung diseases such as chronic obstructive pulmonary disease. Trace gas sensor systems capable of high sensitivi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Chemistry
سال: 2010
ISSN: 0003-2700,1520-6882
DOI: 10.1021/ac100085w