Pengaruh Setting OCR Terhadap Arc Flash Saat Short Circuit Penyulang AK19 Substation Diesel PT KDL
نویسندگان
چکیده
Arc Flash adalah pelepasan energi yang disebabkan oleh arus gangguan atau arching fault ataupun bolted dapat dipicu kelembaban, kegagalan isolasi, human error, serta mekanik. PT. Krakatau Daya Listrik (PT KDL) bergerak di bidang pembangkitan dan pendistribusian listrik Kawasan Industri Krakatau. Salah satu sering terjadi pada jaringan distribusi PT KDL diakibatkan busur api (arc flash). Penelitian ini bertujuan menganalisis pengaruh Setting OCR terhadap arc flash saat short circuit Panel AK19 Substation Diesel tegangan 20kV. Analisis data penelitian mengacu standard IEEE 1584 - 2002 Metode Ralph Lee kemudian disimulasikan dengan software ETAP Power Station menggunakan aktual lapangan. Hasil analisis menunjukkan Fault Clearing Time (FCT) memberikan perubahan cukup signifikan besarnya ditimbulkan ketika hubung singkat 3 fasa. Insiden (E) yaitu 58,35 Cal/cm2 FCT sebesar 0,3 s panel 20 kV, insiden dihasilkan analisa paling kecil 5,8 0,03 s. Hal membuktikan bahwa semakin cepat maka besar kecil, sebaliknya lama terjadi. Gangguan sangat dipengaruhi perhitungan jarak batas perlindungan. Berdasarkan tabel Hazard Risk Category (HRC) diketahui kategori Personal Protective Equipment (PPE) sesuai NFPA 70E 2018.
منابع مشابه
Pengaruh Perangkat Server Terhadap Kualitas Pengontrolan Jarak Jauh Melalui Internet
Internet sangat membantu dalam memperbaiki kualitas kehidupan manusia. Hampir semua bidang kehidupan manusia dapat diakses menggunakan internet. Manusia terbantu dengan adanya internet yang menyediakan segala macam informasi yang dibutuhkan. Seiring dengan perkembangan infrastuktur jaringan internet maka pengontrolan jarak jauh mulai berubah menggunakan media internet. Pada penelitian ini digun...
متن کاملPreventing Glitches Circuit in Flash ADC
The purpose of this paper is to design a prevented glitch circuit (PGC) to avoid the destroyed that is caused to glitch in the paralleling comparator Flash ADC. The advantages of this prevented glitch circuit are high-speed, lower power consumption, and size effective, furthermore, it also reduce the faults. We used the TSPC’s D flip-flop to achieve this prevented glitch circuit where reduces a...
متن کاملOn-Line Quality Monitoring in Short-Circuit Gas Metal Arc Welding
This paper addresses the problems involved in the automatic monitoring of the weId quality produced by robotized short-arc welding. A simple statistical change detection algorithm for the weld quality, the repeated Sequential Probability Ratio Test (SPRT), was used. The algorithm may similarly be viewed as a cumulative sum (CUSUM) type test, and is well-suited to detecting sudden minor changes ...
متن کاملEffect of extracorporeal irradiation on segmental bone autograft incorporation in Sprague-Dawley rats
Latar belakang: Autograft tulang digunakan pada operasi rekonstruksi kasus tumor tulang. Extracorporeal irradiation (ECI) pada tulang digunakan untuk membunuh sel tumor. Namun radiasi juga menimbulkan efek negatif terhadap osteoinduksi dan osteogenensis untuk inkorporasi autograft tulang. Penelitian ini bertujuan mempelajari pengaruh iradiasi dengan dosis 50-300 Gy terhadap kemampuan inkorporas...
متن کاملIntracardiac short circuit.
In the past few years many centres have tended to prefer the pervenous to the transthoracic approach when implanting permanent pacemakers because of the reduced hospital stay and the lower postoperative morbidity. The disadvantages of this approach, however, are an increased failure rate and a greater incidence of late complications associated with the electrode. It may change in position and m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Teknologi Elektro
سال: 2023
ISSN: ['2086-9479', '2621-8534']
DOI: https://doi.org/10.22441/jte.2023.v14i2.004