Petechial and subcutaneous hemorrhage with blister formations in right upper extremity during cardiopulmonary bypass by axillary artery cannulation
نویسندگان
چکیده
منابع مشابه
Petechial and subcutaneous hemorrhage with blister formations in right upper extremity during cardiopulmonary bypass by axillary artery cannulation
A 72-year-old man underwent aortic valve replacement and coronary artery bypass graft using cardiopulmonary bypass with right axillary artery cannulation. After undraping, petechial and subcutaneous hemorrhage with blister formations were found in right upper extremity. Axillary artery cannula was considered to compress right subclavian and disturb venous return in the right subclavian vein, wh...
متن کاملTranscutaneous axillary artery cannulation.
The axillary artery may be an alternative cannulation site for patients with diffused atherosclerosis, aortic dissection, and aneurysm. There are different techniques for axillary artery cannulation that can be performed easily with a transcutaneous approach. Small incision necessity, less dissection, and good wound healing are other advantages of this technique.
متن کاملCardiopulmonary bypass via common carotid artery cannulation in redo sternotomy
There are certain situations in redo cardiac surgery in adults where it may not be possible to use alternate arterial cannulation sites like the common femoral artery and axillary artery. We report a case where we established safe cardiopulmonary bypass with common carotid artery cannulation in an adult patient. The patient underwent aortic valve replacement for severe aortic regurgitation 8 mo...
متن کاملAxillary artery in cardiopulmonary bypass: indications and results.
OBJECTIVES To determine indications and results of axillary artery cannulation for cardiopulmonary bypass. METHODS From January 2005 through December 2008, axillary artery cannulation was used in 48 patients. Mean age was 62 +/- 11 years and 33 (69%) patients were males. Axillary artery was approached by infraclavicular incision and the cannula introduced in a 8 millimeter Dacron side graft. ...
متن کاملAxillary artery cannulation
Percutaneous cannulation of the axillary artery is a safe and appropriate means of intervention for invasive blood pressure monitoring, particularly in the absence of radial or other peripheral pulses. On five separate occasions the author was called upon to place an indwelling cannula for continuous blood pressure monitoring for patients in whom no distal peripheral pulses were palpable. In ea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JA Clinical Reports
سال: 2015
ISSN: 2363-9024
DOI: 10.1186/s40981-015-0008-3