Pixelated silicon detector for radiation beam profile measurements

نویسندگان

چکیده

A pixelated silicon detector, developed originally for particle physics experiments, was used a beam profile measurement of cobalt-60 (Co-60) irradiator in water phantom. The compared to measured with pinpoint ionization chamber. differences the pixel detector and chamber relative profiles were within approximately 2% maximum, after calculating correction factors Monte Carlo simulations maximum difference decreased 1% maximum. detector’s capability measure pulse-height record an electron spectrum Co-60 beam, results agreed well simulations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Techniques for Intense-Proton-Beam Profile Measurements

In a collaborative effort with industry and several national laboratories, the Accelerator Production of Tritium (APT) facility and the Spallation Neutron Source (SNS) linac are presently being designed and developed at Los Alamos National Laboratory (LANL). The APT facility is planned to accelerate a 100 mA H cw beam to 1.7 GeV and the SNS linac is planned to accelerate a 1 to 4 mA-average, H,...

متن کامل

Characterization Of Pin Diode Silicon Radiation Detector

Bhabha atomic research centre has been exploring some of the unique features of silicon detector in a variety of nuclear structure experiment using high-energy photons and heavy ions projectiles. Current experimental application make use of large area silicon detector with depletion thickness of ~150-1000 μm. The low cost silicon detector shows excellent energy and position resolution. In this ...

متن کامل

Radiation Damage Studies for the DØ Silicon Detector ?

We report on irradiation studies performed on spare production silicon detector modules for the current DØ silicon detector. The lifetime expectations due to radiation damage effects of the existing silicon detector are reviewed. A new upgrade project was started with the goal of a complete replacement of the existing silicon detector. In that context, several investigations on the radiation ha...

متن کامل

Amorphous SilicodCrystalline Silicon Heterojunctions for Nuclear Radiation Detector Applications

Results on the characterization of the elecmcal properties of amorphous silicon-films for the three different growth methods, RF sputtering, PECVD, and LPCVD are reported. The performance of these a-Si films as heterojunctions on high resistivity p-type and n-type crystalline silicon is examined by measuring the noise, leakage current and the alpha particle response of 5 mm diameter detector st...

متن کامل

Optical Radiation Measurements Based on Detector Standards

A near-IR radiometer standard with similar performance to silicon trap-detectors has been developed to calibrate detectors and radiometers for absolute spectral power, irradiance, and radiance responsivities between 950 nm and 1650 nm. The new radiometer standard is utilized at the Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) which is the reference c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiation Measurements

سال: 2023

ISSN: ['1350-4487', '1879-0925']

DOI: https://doi.org/10.1016/j.radmeas.2023.106949