Polystyrene-coated Interdigitated Microelectrode Array to Detect Free Chlorine towards IoT Applications
نویسندگان
چکیده
منابع مشابه
Glucose sensing based on interdigitated array microelectrode.
A micro glucose sensor consisting of an interdigitated array gold microelectrode was developed. The interdigitated array structure, which has 10 microns band width and 10 microns band gap, was fabricated in a small region (2.5 x 5 mm2) on a quartz substrate. Glucose oxidase was chemically fixed onto the electrode surface through self-assembled monolayer of 11-mercaptoundecanoic acid; ferrocenea...
متن کاملPrussian Blue-coated interdigitated array electrodes for possible analytical application
Thin films of iron(W) hexacyanoferrate(I1) (Prussian Blue) were electrochemically deposited on interdigitated array (IDA) electrodes, yielding systems which can be considered as chemiresistors in sensing alkali metal ion concentrations in an adjacent electrolyte. This is due to the fact that the conductivity of the film being measured by a steady-state current on application of a voltage to the...
متن کاملMulti-well microelectrode array recordings detect neuroactivity of ToxCast compounds.
Spontaneous activity in neuronal cultures on microelectrode arrays (MEAs) is sensitive to effects of drugs, chemicals, and particles. Multi-well MEA (mwMEA) systems have increased throughput of MEAs, enabling their use for chemical screening. The present experiments examined a subset of EPA's ToxCast compounds for effects on spontaneous neuronal activity in primary cortical cultures using 48-we...
متن کاملImpedance Immunsensor Based on Interdigitated Array Microelectrode and its Experiment Parameter Optimization
This article accounts for a novel impedance immunosensor based on the specificity reaction of the antigen-antibody and the sensitivity of the interdigitated array microelectrode (IDAM) for the determination of chlorpyrifos residues. The basic knowledge of immunoassay was in relation to its IDAM electrode surface modification, antibody immobilization, bovine serum albumin (BSA) blocking and samp...
متن کاملFlexible three-dimensional microelectrode array for neural applications
A neural electrode array design is proposed with 3 mm long sharpened pillars made from an aluminumbased substrate. The array is composed by 25 electrically insulated pillars in a 5 x 5 matrix, in which each aluminum pillar was precisely machined via dicing saw technique. The result is an aluminum structure with high-aspect-ratio pillars (19:1), each with a tip radius of 10 μm. A thin-film of pl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2019
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.18p460