Prepolarized fast spin-echo pulse sequence for low-field MRI
نویسندگان
چکیده
منابع مشابه
Rapid field-cycling MRI using fast spin-echo.
PURPOSE Fast field-cycling MRI (FFC-MRI) is a technique that promises to expand upon the diagnostic capabilities of conventional MRI by allowing the main field, B0 , to be varied during a pulse sequence, thus allowing access to new types of endogenous contrast. However, this necessitates longer scan times, which can limit the technique's application to clinical research. In this paper, an adapt...
متن کاملOptimized three-dimensional fast-spin-echo MRI.
Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the com...
متن کاملFast Low-Angle Dual Spin-Echo (FLADE): A New Pulse Sequence for Micro-Imaging of Trabecular Bone
J. Magland, B. Vasilic, F. W. Wehrli Laboratory for Structural NMR Imaging, Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, PA, United States Introduction The architecture of trabecular bone plays a pivotal role in conferring strength to the skeleton. Recent advances in MR imaging technology have made possible direct imaging of the 3D architecture of trabecular...
متن کاملUnbiased Nonlinear Filtering of Fast Spin Echo MRI Images
Introduction: The design of filtering methods for denoising the magnitude MRI images is traditionally fulfilled assuming that that image noise is zero-mean Gaussian, as Rician properties of magnitude MRI image noise usually complicates a method both algorithmically and computationally [1]. This widely used assumption leads to the biased filtering results, the bias increases as local signal-to-n...
متن کاملFast Spin Echo Imaging
In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...