Preventing Chaotic Motion in Tapping-Mode Atomic Force Microscope

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging bandwidth of the tapping mode atomic force microscope probe

János Kokavecz,1,* Othmar Marti,2 Péter Heszler,3,4 and Ádám Mechler5,† 1Department of Optics and Quantum Electronics, University of Szeged, P.O. Box 406, H-6701 Szeged, Hungary 2Department of Experimental Physics, University of Ulm, Albert-Einstein-Allee 11 D-89069 Ulm, Germany 3Research Group on Laser Physics of the Hungarian Academy of Sciences, P.O. Box 406, H-6701 Szeged, Hungary 4The Ångs...

متن کامل

Tapping mode atomic force microscopy in liquid

We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode AFhif in liquid. Acoustic modes in the liquid excite the canti1eve.r. On soft samples, e.g., biolog...

متن کامل

Tip Effect of the Tapping Mode of Atomic Force Microscope in Viscous Fluid Environments

Atomic force microscope with applicable types of operation in a liquid environment is widely used to scan the contours of biological specimens. The contact mode of operation allows a tip to touch a specimen directly but sometimes it damages the specimen; thus, a tapping mode of operation may replace the contact mode. The tapping mode triggers the cantilever of the microscope approximately at re...

متن کامل

Note: ferrule-top atomic force microscope. II. Imaging in tapping mode and at low temperature.

In a recent paper [D.Chavan et al., Rev. Sci. Instrum. 81, 123702 (2010)] we have demonstrated that ferrule-top cantilevers, obtained by carving the end of a ferruled fiber, can be used for contact mode atomic force microscopy in ambient conditions. Here we show that those probes can provide tapping mode images at both room and cryogenic temperatures (12 K).

متن کامل

Topography imaging with a heated atomic force microscope cantilever in tapping mode.

This article describes tapping mode atomic force microscopy (AFM) using a heated AFM cantilever. The electrical and thermal responses of the cantilever were investigated while the cantilever oscillated in free space or was in intermittent contact with a surface. The cantilever oscillates at its mechanical resonant frequency, 70.36 kHz, which is much faster than its thermal time constant of 300 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Control, Automation and Electrical Systems

سال: 2014

ISSN: 2195-3880,2195-3899

DOI: 10.1007/s40313-014-0144-4