Quantification of Electron Beam Heating Effect in TEM
نویسندگان
چکیده
منابع مشابه
Pulsed Electron-Beam Heating
A pulsed, 20 kv electron beam is focussed upon a vapor-deposited thermocouple, and the resulting temperature vs. time response is studied. The experimental data show much scatter, but are consistent with the theoretical prediction that the characteristic thermal response time T is proportional to d , where d is the beam diameter at the thermocouple. From these data, for the soft-glass substrate...
متن کاملEffect of Electron Beam Irradiation on Viability of Sarcocystis spp. in Beef
Background: Sarcocystosis is one of the most distributed parasitic diseases over the world, caused by Sarcocystis spp. In this study, we assessed the effect of electron beam irradiation on the viability of Sarcocystis spp. in beef. Methods: Experimental beef groups were irradiated by four different electron beam doses of 1, 2, 3, and 4 kGy, at intervals of 0 and 24 h after irradiation, then t...
متن کاملInvestigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic
Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...
متن کاملHeating of TEM specimens during ion milling.
Sample heating during preparation of electron-thin specimens for observation in transmission electron microscopy (TEM) can produce artefacts which invalidate observations. This is particularly true of two-phase materials such as metal matrix composites, for which sample cooling with liquid nitrogen cannot be used to preserve the substructure during milling. A series of experiments is conducted ...
متن کاملEffect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy
Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2017
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927617009497