Radar-Based, Simultaneous Human Presence Detection and Breathing Rate Estimation
نویسندگان
چکیده
منابع مشابه
Simulation-Based Radar Detection Methods
In this paper, radar detection based on Monte Carlo sampling is studied. Two detectors based on Importance Sampling are presented. In these detectors, called Particle Detector, the approximated likelihood ratio is calculated by Monte Carlo sampling. In the first detector, the unknown parameters are first estimated and are substituted in the likelihood ratio (like the GLRT method). In the sec...
متن کاملDetection of Human Breathing and Heartbeat by Remote Radar
The radar capable to detect and perform diagnostics of a state of the human being behind obstacles and in conditions of bad visibility could be used for the manifold applications. The potential consumers of the radar are: rescue services, antiterrorist detachments and law-enforcement bodies. It is possible also to use this device in medicine. In this paper, the experiments with using of continu...
متن کاملSimulation-Based Radar Detection Methods
In this paper, radar detection based on Monte Carlo sampling is studied. Two detectors based on Importance Sampling are presented. In these detectors, called Particle Detector, the approximated likelihood ratio is calculated by Monte Carlo sampling. In the first detector, the unknown parameters are first estimated and are substituted in the likelihood ratio (like 
the GLRT method). In the s...
متن کاملVisual Receding Horizon Estimation for human presence detection
This paper deals with human presence detection by using a receding horizon estimator based on computer vision results. The visual position estimation problem is formulated into a nonlinear constrained optimization problem in the image plane. A global model combining the behavior of the human motion and the camera model is used to estimate the evolution of the visual features on a past finite ho...
متن کاملBreathing Rate Estimation from the Electrocardiogram and Photoplethysmogram: A Review
Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, el...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2021
ISSN: 1424-8220
DOI: 10.3390/s21103529