Reactive Power Control by Cascaded Thyristor Bridges
نویسندگان
چکیده
منابع مشابه
Hybrid Cascaded H-bridges Multilevel Motor Drive Control
This paper presents a hybrid cascaded H-bridge multilevel motor drive control scheme for electric/hybrid electric vehicles where each phase of a three-phase cascaded multilevel converter can be implemented using only a single DC source and capacitors for the other DC sources. Traditionally, each phase of a three-phase cascaded multilevel converter requires n DC sources for 2n + 1 output voltage...
متن کاملemittance control in high power linacs
چکیده این پایان نامه به بررسی اثر سیم پیچ مغناطیسی و کاوه یِ خوشه گر با بسامد رادیویی بر هاله و بیرونگراییِ باریکه هایِ پیوسته و خوشه ایِ ذرات باردار در شتابدهنده های خطیِ یونی، پروتونی با جریان بالا می پردازد و راه حل هایی برای بهینه نگهداشتن این کمیتها ارایه می دهد. بیرونگرایی یکی از کمیتهای اساسی باریکه هایِ ذرات باردار در شتابدهنده ها است که تاثیر قابل توجهی بر قیمت، هزینه و کاراییِ هر شتابدهند...
Reactive Compensation Capability Of Fixed Capacitor Thyristor Controlled Reactor For Load Power Factor Improvement: A Review
Reactive power compensation capability of a fixed capacitor thyristor controlled reactor type static VAr compensator is being investigated in this paper. The TCR has the power transfer controlling capability only in the lagging power factor range. The range of TCR can be extended by connecting a fixed capacitor in shunt with the TCR. The compensated reactive power can be selectively controlled ...
متن کاملA Simple Multi-objective Control for Cascaded Hydro Power Plants
This paper presents a simple multi-objective control technique for cascaded hydro power plants, based on a centralized distributed power control system and local water level controllers. This effective power management solution enables to guarantee the generation program following with a very good accuracy, to participate to power-frequency Ancillary Services with the dynamic performance requir...
متن کاملVoltage stress minimization by optimal reactive power control
A standard operational requirement in power systems is that the voltage magnitudes lie within prespecified bounds. Conventional engineering wisdom suggests that such a tightly-regulated profile, imposed for system design purposes and good operation of the network, should also guarantee a secure system, operating far from static bifurcation instabilities such as voltage collapse. In general howe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1979
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1972.99.410