Reference-based Maximum Upslope: A CBF Quantification Method without Using Arterial Input Function in Dynamic Susceptibility Contrast MRI

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference-based Cbf Index of Maximum Upslope without Using Arterial Input Function in Dynamic Susceptibility Contrast Mri: Comparison with Deconvolution Method

Introduction Accurate measurements of arterial input function (AIF) are indispensable for quantification of perfusion parameters such as MTT, CBV and CBF based on the indicator dilution theory in perfusion imaging using vascular contrast materials. Quantification of cerebral perfusion using deconvolution methods with DSC-MRI has been reported on [1-2]. However, accurately measuring AIF in DSC-M...

متن کامل

Dynamic susceptibility contrast MRI with localized arterial input functions.

Compared to gold-standard measurements of cerebral perfusion with positron emission tomography using H(2)[(15)O] tracers, measurements with dynamic susceptibility contrast MR are more accessible, less expensive, and less invasive. However, existing methods for analyzing and interpreting data from dynamic susceptibility contrast MR have characteristic disadvantages that include sensitivity to in...

متن کامل

Evaluation of signal formation in local arterial input function measurements of dynamic susceptibility contrast MRI.

Correct arterial input function (AIF) measurements in dynamic susceptibility contrast-MRI are crucial for quantification of the hemodynamic parameters. Often a single global AIF is selected near a large brain-feeding artery. Alternatively, local AIF measurements aim for voxel-specific AIFs from smaller arteries. Because local AIFs are measured higher in the arterial-tree, it is assumed that the...

متن کامل

Tumor Arterial Input Function (AIF) estimation in DCE-MRI studies using a multiple reference tissue method

C. Yang, W. M. Stadler, M. Medved, G. S. Karczmar University of Chicago, Chicago, IL, United States Introduction: Accurate estimation of the arterial input function (AIF) is essential for quantitative analysis of DCE-MRI data. We have previously demonstrated that a common AIF can be estimated from the contrast agent concentration versus time curves (Ct(t)) in two reference tissues with differen...

متن کامل

Blind estimation of the arterial input function in dynamic contrast-enhanced MRI using purity maximization.

Uncertainty in arterial input function (AIF) estimation is one of the major errors in the quantification of dynamic contrast-enhanced MRI. A blind source separation algorithm was proposed to determine the AIF by selecting the voxel time course with maximum purity, which represents a minimal contamination from partial volume effects. Simulations were performed to assess the partial volume effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medical Sciences

سال: 2009

ISSN: 1880-2206,1347-3182

DOI: 10.2463/mrms.8.107