Reliability of Ankle–Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
نویسندگان
چکیده
منابع مشابه
assessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Reliability of the Lido Linea closed kinetic chain isokinetic dynamometer.
Due to increasing emphasis on closed kinetic chain exercises in rehabilitation, there is a need to objectively quantify their effectiveness. The purpose of this study was to determine the test-retest reliability of the peak force and total work scores during a concentric isokinetic leg press pattern using the Lido Linea closed kinetic chain isokinetic dynamometer. The static calibration of forc...
متن کاملValidity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength
PURPOSE To determine whether the handheld dynamometer (HHD) is an appropriate tool to assess and quantify peak hip extension strength in prone standing position by (1) evaluating the concurrent validity of the HHD versus an isokinetic dynamometer (IKD), (2) establishing the minimal detectable change (MDC), and (3) determining the validity of single-trial versus multi-trial measures. METHOD A ...
متن کاملReliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary c...
متن کاملReliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer
The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23±3 years) underwent three testing sessions, two on the same day ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicina
سال: 2018
ISSN: 1648-9144
DOI: 10.3390/medicina54030043