Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor

Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteristics of aquifers using large-coil (typically 50-150 m) sensors has been discussed based on forwa...

متن کامل

Design of a Matching Network for a High-Sensitivity Broadband Magnetic Resonance Sounding Coil Sensor

The magnetic resonance sounding (MRS) technique is a non-invasive geophysical method that can provide unique insights into the hydrological properties of groundwater. The Cu coil sensor is the preferred choice for detecting the weak MRS signal because of its high sensitivity, low fabrication complexity and low cost. The tuned configuration was traditionally used for the MRS coil sensor design b...

متن کامل

synthesis of amido alkylnaphthols using nano-magnetic particles and surfactants

we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.

15 صفحه اول

Design of Meter-Scale Antenna and Signal Detection System for Underground Magnetic Resonance Sounding in Mines

Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to un...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2017

ISSN: 1424-8220

DOI: 10.3390/s17092127