Retinal Vessel Diameter Measurement Using Unsupervised Linear Discriminant Analysis
نویسندگان
چکیده
منابع مشابه
Retinal Vessel Diameter Measurement Using Unsupervised Linear Discriminant Analysis
An automatic vessel diameter measurement technique based on linear discriminant analysis (LDA) has been proposed. After estimating the vessel wall, the vessel cross-section profile is divided into three regions: two corresponding to the background and one to the vessel. The algorithm was tested on more than 5000 cross-sections of retinal vessels from the REVIEW dataset through comparative study...
متن کاملBlood vessel diameter Measurement on retinal Image
Accurate measurement of vessel diameters on retinal images plays an important part in diagnosing cardiovascular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. In this study we develop new method based on computer aided to determine the width of retinal blood vessels by analysing the color fundus image. Retinal vessel diameter was measured based on bloo...
متن کاملUnsupervised Retinal Vessel Segmentation Using Combined Filters.
Image segmentation of retinal blood vessels is a process that can help to predict and diagnose cardiovascular related diseases, such as hypertension and diabetes, which are known to affect the retinal blood vessels' appearance. This work proposes an unsupervised method for the segmentation of retinal vessels images using a combined matched filter, Frangi's filter and Gabor Wavelet filter to enh...
متن کاملVessel Cross-Sectional Diameter Measurement on Color Retinal Image
Vessel cross-sectional diameter is an important feature for analyzing retinal vascular changes. In automated retinal image analysis, the measurement of vascular width is a complex process as most of the vessels are few pixels wide or suffering from lack of contrast. In this paper, we propose a new method to measure the retinal blood vessel diameter which can be used to detect arteriolar narrowi...
متن کاملMeasurement of retinal blood vessel width using computerized image analysis.
We report a new method for quantitating retinal blood vessel width from fluorescein angiogram negatives using a computerized image analyser. Interuser and intrauser variability were 3 to 4 times lower than reported with older methods. In addition, model blood vessels were used to test the accuracy of our method under four clinically relevant conditions: variations in vessel width, fluorescein c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ISRN Ophthalmology
سال: 2012
ISSN: 2090-5696
DOI: 10.5402/2012/151369