SANDD: A directional antineutrino detector with segmented <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="d1e787" altimg="si39.svg"><mml:msup><mml:mrow /><mml:mrow><mml:mn>6</mml:mn></mml:mrow></mml:msup></mml:math>Li-doped pulse-shape-sensitive plastic scintillator
نویسندگان
چکیده
We present a characterization of small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose near-field reactor monitoring with sensitivity to direction. comprises three different types module. A detailed Monte Carlo simulation code was developed match validate performance each modules. The combined model then used produce prediction entire detector. Analysis cuts were established isolate inverse beta decay events while rejecting large fraction backgrounds. neutron positron detection efficiencies are estimated be 34.8% 80.2%, respectively, coincidence efficiency is 71.7%, resulting in 20.0% ± 0.2%(stat.) 2.1%(syst.). predicted directional produces an uncertainty 20∘ azimuthal direction per 100 detected events.
منابع مشابه
Neutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout
An EJ-299-34 plastic scintillator with silicon photomultiplier (SiPM) readout was used to measure the fast neutron output of a pulsed Thermo-Fisher A-325 Deuterium-Tritium sealed tube neutron generator (STNG). The SiPM signals were handled by a prototype digital pulse processing system, based on a free-running analogue to digital converter feeding a digital signal processor (DSP). Pulse shape d...
متن کاملComparative analysis of pulse shape discrimination methods in a Li loaded plastic scintillator
Three algorithms for discriminating between fast neutrons, thermal neutrons and gamma rays in a Li loaded plastic scintillator have been compared. Following a literature review of existing pulse shape discrimination techniques, the performance of the charge comparison method, triangular filtering and frequency gradient analysis were investigated in this work. The scintillator was exposed to thr...
متن کاملAntineutrino geophysics with liquid scintillator detectors
Detecting the antineutrinos emitted by the decay of radioactive elements in the mantle and crust could provide a direct measurement of the total abundance of uranium and thorium in the Earth. In calculating the antineutrino flux at specific sites, the local geology of the crust and the background from the world’s nuclear power reactors are important considerations. Employing a global crustal ma...
متن کاملLITHIUM GADOLINIUM BORATE IN PLASTIC SCINTILLATOR AS AN ANTINEUTRINO DETECTION MATERIAL by
Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including s...
متن کاملAn Embedded Microprocessor Design for the Pulse Shape Discrimination of a Plastic Scintillating Neutron Detector
Kaua‘i Community College (Kaua‘i CC) is presently participating in an effort to develop a space industry in Hawai‘i. This effort includes future launches of University of Hawai‘i supported micro-class satellites from the Pacific Missile Range Facility at Barking Sands, Kaua‘i. Kaua‘i CC’s participation is represented by operation and maintenance of a ground station, located on campus, to suppor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research
سال: 2021
ISSN: ['1872-9576', '0168-9002']
DOI: https://doi.org/10.1016/j.nima.2021.165409