Hybrid scatter correction for CT imaging.
The purpose of this study was to develop and evaluate the hybrid scatter correction algorithm (HSC) for CT imaging. Therefore, two established ways to perform scatter correction, i.e. physical scatter correction based on Monte Carlo simulations and a convolution-based scatter correction algorithm, were combined in order to perform an object-dependent, fast and accurate scatter correction. Based...
متن کاملScatter Correction Methods in Dimensional CT
The purpose of this study was to evaluate different approaches for scatter artifact reduction in the field of dimensional computed tomography (CT). The methods we investigated can be subdivided into one software-based method and three hardware-based methods. The software-based method uses a Monte Carlo scatter simulation to estimate scatter intensities for an initial model of the geometrical an...
متن کاملScatter correction for cone-beam CT in radiation therapy.
Cone-beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x-ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solutio...
متن کاملNoise suppression in scatter correction for cone-beam CT.
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The high-frequency scatter noise remains in the projection images even after a perfect scatter correction. In this paper, using a clinical CBCT system and a measurement-based scatter correction, the a...
متن کاملFeasibility of improving cone‐beam CT number consistency using a scatter correction algorithm
The study was to explore the feasibility of improving cone-beam CT (CBCT) number (corresponding to the Hounsfield units in computed tomography) consistency using a scatter-correction algorithm, with the aim of using CBCT images for treatment planning with density correction. A scatter correction algorithm was applied to a Varian OBI CBCT and an Elekta XVI CBCT, and was evaluated for improving C...