Seismic Retrofit of Flat Plate Structures

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Retrofit for Electric Power Systems

This paper develops a two-stage stochastic program and solution procedure to optimize the selection of seismic retrofit strategies to increase the resilience of electric power systems to earthquake hazards. The model explicitly considers the range of earthquake events that are possible and, for each, an approximation to the distribution of damage that is experienced. This is important because e...

متن کامل

Using Composites in Seismic Retrofit Applications

This report was prepared to provide a comprehensive review of the state-of-the-art for using composite materials for seismic retrofit applications. The emphasis is on seismic retrofit of reinforced concrete columns. The report is presented in eleven chapters. Chapters 1–3 provide a basic introduction to composite materials, including discussions on the types of matrix and reinforcement material...

متن کامل

External seismic pre-isolation retrofit design

This technical note outlines the design of an external seismic pre-isolation system proposed for use in LIGO Livingston. The goal is to reduce the effects of the site’s excess ground noise in the 1 3 Hz frequency band, allowing detector noise performance equivalent to that of the 4 km LIGO Hanford detector. The center histogram in Figure 8 shows the most troubling aspect of the excess noise qui...

متن کامل

Energy-Based Design Criterion of Dissipative Bracing Systems for the Seismic Retrofit of Frame Structures

Direct sizing criteria represent useful tools in the design of dissipative bracing systems for the advanced seismic protection of existing frame structures, especially when incorporated dampers feature a markedly non-linear behaviour. An energy-based procedure is proposed herein to this aim, focusing attention on systems including fluid viscous devices. The procedure starts by assuming prefixed...

متن کامل

Seismic Evaluation and Retrofit of Gas Stations: Case Study

Iran is a country with high seismicity while Tehran, the capital city is home to more than 10 million people which are located on the highest seismic zone of the country. There exist 153 gas stations throughout the metropolitan which are constructed to old building codes with little or no attention to the seismic considerations. In this study which was supported by the National Oil Company, fir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil Engineering and Architecture

سال: 2013

ISSN: 2332-1091,2332-1121

DOI: 10.13189/cea.2013.010102