Laser-Induced Incandescence of Soot at High Pressures
Laser-Induced Incandescence of Soot at High Pressures Sanaz Ghasemi Master of Applied Science Graduate Department of Aerospace Science and Engineering University of Toronto 2012 Measurements of soot emission properties are of interest in both fundamental research and combustion-based industries. Laser-induced incandescence of soot particles is a novel technique that allows unobtrusive measureme...
متن کاملLaser-induced incandescence for soot particle size measurements in premixed flat flames.
Measurements of soot properties by means of laser-induced incandescence (LII) and combined scattering-extinction were performed in well-characterized premixed ethylene-air flames. In particular, the possibility of using LII as a tool for quantitative particle sizing was investigated. Particle sizes were evaluated from the temporal decay of the LII signal combined with heat balance modeling of l...
متن کاملLaser Induced Incandescence and Particle Size
The cooling rate of soot particles after laser induced incandescence (LII) is thought to provide an estimate of the size of nanoparticles (NPs) in the engine exhaust. It is shown that cooling rate is not applicable to NPs, and instead is only a measure of the size of micron-sized particles. The problem is that the conservation of absorbed laser photon energy in NPs is subject to quantum electro...
متن کاملSize Distribution Measurement of Candle\'s Soot Nanoparticles by Using Time Resolved Laser Induced Incandescence
Time resolved laser induced incandescence (LII) technique is used to measure size distribution of soot nanoparticles of candle's flame. Pulsed Nd:YAG laser is used to heat nanoparticles to incandescence temperature and the resulting signal is measured. Mass and energy balance equations are numerically solved to calculate temperature of soot particles in low fluence regime. Assuming Plank black ...
متن کاملLaser-induced incandescence and multi-line NO LIF thermometry for soot diagnostics at high pressures
Laser-induced incandescence (LII) is investigated in laminar premixed flat ethylene/air flames at pressures up to 5 bar in a recently constructed high-pressure burner. Time-resolved LII signals were compared with a numerical model considering the influence of pressure on the LII signal decay. Peak particle temperatures after laser heat up were measured by the detection of the LII signal at two ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics B
سال: 2015
ISSN: 0946-2171,1432-0649
DOI: 10.1007/s00340-015-6009-0