Separation and Estimation of Process-Related Impurities of Gefitinib by Reverse-Phase High-Performance Liquid Chromatography
نویسندگان
چکیده
منابع مشابه
Separation and determination of process-related impurities of industrial chlorpyriphos by reversed-phase high-performance liquid chromatography.
متن کامل
Separation and determination of synthetic impurities of sildenafil (Viagra) by reversed-phase high-performance liquid chromatography.
A simple and rapid high-performance liquid chromatographic method for the separation and determination of process-related impurities of sildenafil was developed. The separation was achieved on a reversed-phase C18 column using acetonitrile-0.05 M potassium dihydrogen orthophosphate (70:30 v/v) as a mobile solvent at a flow rate of 1.0 ml/min and UV detection at 230 nm. The method was used not o...
متن کاملReverse-phase chromatography of polar biological substances: separation of catechol compounds by high-performance liquid chromatography.
Catecholamines and their metabolites have been separated isocratically by reverse-phase chromatography with aqueous (no organic solvent admixed) eluents. Unlike ion-exchange or ion-pair chromatography, mixtures of both acidic and basic substances can be separated in a single chromatographic run, because the retention is governed by hydrophobic interactions between the nonpolar moiety of the sol...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chromatographic Science
سال: 2013
ISSN: 0021-9665,1945-239X
DOI: 10.1093/chromsci/bmt116