Separation of collagen cyanogen bromide-derived peptides by reversed-phase high-performance liquid chromatography
                    
                        
                            نویسندگان
                            
                            
                        
                        
                    
                    
                    چکیده
منابع مشابه
Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of a complex mixture of heparin-derived oligosaccharides using reversed-phase high-performance liquid chromatography.
A reversed-phase ion-pairing high-performance liquid chromatography (RP-HPIPC) method for the separation of a complex mixture of heparin-derived oligosacchrides has been developed by a stepwise optimization of the mobile phase, in which the concentration of ion-pairing reagent, mobile phase pH, and acetonitrile concentration were varied. The resolution of more than 30 oligosaccharide components...
متن کاملSeparation and determination of synthetic impurities of sildenafil (Viagra) by reversed-phase high-performance liquid chromatography.
A simple and rapid high-performance liquid chromatographic method for the separation and determination of process-related impurities of sildenafil was developed. The separation was achieved on a reversed-phase C18 column using acetonitrile-0.05 M potassium dihydrogen orthophosphate (70:30 v/v) as a mobile solvent at a flow rate of 1.0 ml/min and UV detection at 230 nm. The method was used not o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biochemical Journal
سال: 1980
ISSN: 0264-6021
DOI: 10.1042/bj1910253