Setting method of parameters for SN transition fault current limiter into 6.6kV distribution system
نویسندگان
چکیده
منابع مشابه
The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System
In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...
متن کاملthe impact of superconducting fault current limiter locations on voltage sag in power distribution system
in this paper, the impacts of installing superconducting fault current limiter (sfcl)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (dg). among various sfcls, the hybrid type with a superconducting element in parallel with a current limiting reactor (clr) is selected. this is more effective than resisto...
متن کاملFault Current Limiter for a Distributed Power System
The up-gradation of an Electrical power generation network results in higher levels of short circuit fault current. Thereby, the existing protection equipment like circuit breakers, isolators and fuses become under capacity and not capable of withstanding higher short circuit currents. Thus the system is highly vulnerable to the adverse effects of short circuits. Replacing the whole protection ...
متن کاملProtection Principle for a DC Distribution System with a Resistive Superconductive Fault Current Limiter
A DC distribution system, which is suitable for access to distributed power generation and DC loads, is one of the development directions in power systems. Furthermore, it could greatly improve the energy efficiency and reduce the loss of power transportation. The huge short circuit current is always a great threat to the safety of the components, especially the capacitors and diodes. A resisti...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2008
ISSN: 1742-6596
DOI: 10.1088/1742-6596/97/1/012322