Short echo time MR spectroscopic imaging of the lung parenchyma

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short echo time MR spectroscopic imaging for neonatal pediatric imaging.

A short echo time (30 milliseconds) MR spectroscopic imaging pulse sequence was implemented for applications of neonatal brain imaging. Multiple spatial saturation bands were used to eliminate strong signals originating from the subcutaneous lipids to enable volumetric region coverage. Metabolite signal intensity-to-noise ratio < or =40 was acquired in 9 minutes of scan time over an 8 x 8 x 8 s...

متن کامل

Ultra-short echo time (UTE) MR imaging of the lung: assessment of tissue density in the lung parenchyma

Introduction: Computed tomography (CT) is the standard method for imaging of the lung parenchyma but carries potential radiation risk. One of the fundamental difficulties in MR imaging of the lung is the existence of severe magnetic field susceptibility effects arising from the massive interface between the interstitial tissue and alveolar airspace (1). Consequently, the lung parenchyma has ver...

متن کامل

Ultra-short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous mice

M. Takahashi, O. Togao, M. Obara, M. van Cauteren, Y. Ohno, C. Malloy, M. Kuro-o, and I. Dimitrov Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, United States, Philips Electronics Japan, Tokyo, Japan, Radiology, Kobe University Graduate School of Medicine, Hyogo, Japan, Pathology, University of Texas Southwestern Medical Center, Dallas, Texas, ...

متن کامل

Low-grade glioma: correlation of short echo time 1H-MR spectroscopy with 23Na MR imaging.

BACKGROUND AND PURPOSE There is considerable variability in the clinical behavior and treatment response of low-grade (WHO grade II) gliomas. The purpose of this work was to characterize the metabolic profile of low-grade gliomas by using short echo time (1)H-MR spectroscopy and to correlate metabolite levels with MR imaging-measured sodium ((23)Na) signal intensity. Based on previous studies, ...

متن کامل

Test-retest reliability and reproducibility of short-echo-time spectroscopic imaging of human brain at 3T.

A 1H magnetic resonance spectroscopic imaging study at 3T and short echo time was conducted to evaluate both the reproducibility, as measured by the interscan coefficient of variation (CV), and test-retest reliability, as measured by the intraclass correlation coefficient (ICC), of measurements of glutamate (Glu), combined glutamate and glutamine (Glx), myo-inositol (mI), N-acetylaspartate, cre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Magnetic Resonance Imaging

سال: 2002

ISSN: 1053-1807,1522-2586

DOI: 10.1002/jmri.10113