Short T2 contrast with three-dimensional ultrashort echo time imaging
نویسندگان
چکیده
منابع مشابه
Designing long-T2 suppression pulses for ultrashort echo time imaging.
Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 valu...
متن کاملMapping T2 Relaxation Time of Cerebral Metabolites using Three Dimensional Proton-Echo Planar Spectroscopic Imaging (PEPSI)
H. Ho, S. Tsai, Y. Lin, S. Posse, and F. Lin Electrical Engineering, Chang Gung University, Tao Yuan, Taiwan, Electronic Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, Neurology, University of New Mexico School of Medicine, Albuquerque, NM, United States, Electrical and Computer Engineering, University of New Mexico, Albuquerque, NM, United States, Biomedical...
متن کاملUsing adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.
Ultrashort echo time (UTE) imaging is a technique that can visualize tissues with sub-millisecond T(2) values that have little or no signal in conventional MRI techniques. The short-T(2) tissues, which include tendons, menisci, calcifications, and cortical bone, are often obscured by long-T(2) tissues. This paper introduces a new method of long-T(2) component suppression based on adiabatic inve...
متن کاملSimultaneous T2 and T2* dynamic susceptibility contrast perfusion imaging using a multi-echo parallel imaging approach
Introduction. The utility of multi-echo DSC with gradient echo (GRE) EPI has recently been demonstrated for improved AIF determination, T1 independent contrast concentration estimation, and SNR recovery. In order to quantify the difference between the static and dynamic dephasing regimes, a gradient and spin echo (GRASE) multi-shot multi-echo EPI sequence is demonstrated. The hemodynamic parame...
متن کاملWater/Fat Separation of Short T2* Tissue using Multi-echo Ultra-short Echo Time (UTE) Imaging and IDEAL
K. Wang, H. Yu, J. Brittain, S. Reeder, and J. Du Medical Physics, University of Wisconsin-Madison, Madison, WI, United States, Applied Science Laboratory, GE Healthcare, Menlo Park, CA, United States, Applied Science Laboratory, GE Healthcare, Madison, WI, United States, Radiology, University of Wisconsin-Madison, Madison, WI, United States, Radiology, University of California, San Diego, San ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance Imaging
سال: 2011
ISSN: 0730-725X
DOI: 10.1016/j.mri.2010.11.003