Simultaneous Determination of Magnesium (Mg2+) and Ammonium (NH4+) by Flow Injection Analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric simultaneous determination of nitrite, nitrate and ammonium in soils by flow injection analysis.

A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-Ilosvay reaction. The formed azo dye was measured at 543 nm. The influenc...

متن کامل

Simultaneous determination of lithium, sodium and potassium in blood serum by flame photometric flow-injection analysis.

A simultaneous flow-injection analysis (FIA) manifold that could analyse three ions from a single injection was designed, constructed, calibrated and used successfully to analyse Li(+), Na(+) and K(+). This FIA method was 10 times faster than the batch technique. The sample volume required was a fraction of about 1/110 to 1/75 that of the batch technique. The outputs were quite reproducible and...

متن کامل

Simultaneous spectrophotometric determination of uranium and thorium by flow injection analysis using selective masking.

A flow injection system for the simultaneous determination of uranium and thorium has been developed by using selective masking and a spectrophotometric detector with two flow cells aligned with the same optical path. The injected sample solution was first mixed with a reagent solution containing Chromazurol S (CAS) and cetyltrimethylammonium chloride (CTMAC), and the total absorbance of uraniu...

متن کامل

Simultaneous spectrophotometric determination of nitrite and nitrate by flow-injection analysis.

An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, ...

متن کامل

Simultaneous enzymatic/electrochemical determination of glucose and L-glutamine in hybridoma media by flow-injection analysis.

A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal ILMU DASAR

سال: 2018

ISSN: 2442-5613,1411-5735

DOI: 10.19184/jid.v19i1.5483