STIFFNESS DESIGN SEQUENCE OF A SHEAR BUILDING WITH MAXWELL TYPE VISCOUS DAMPERS FOR SPECIFIED SEISMIC DRIFTS
نویسندگان
چکیده
منابع مشابه
Application of a Direct Procedure for the Seismic Retrofit of a R/C School Building Equipped with Viscous Dampers
Several design methods aimed at sizing the viscous dampers to be inserted in building structures have been proposed in the last decades. Among others, the authors proposed a five-step procedure that guides the practical design from the choice of a target reduction in the seismic response of the structural system (with respect to the response of a structure without any additional damping devices...
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Seismic Response Study of Asymmetric Systems with Linear and Nonlinear Fluid Viscous Dampers
This investigation is concerned with application of nonlinear fluid viscous dampers for asymmetric-plan systems. For this purpose, the behavior of nonlinear fluid viscous dampers is summarized first followed by the effects of damper nonlinearity on seismic response of asymmetric systems. It is shown that the peak force in nonlinear damper tends to be smaller compared to linear damper. However, ...
متن کاملevaluation of stiffness and strength degradations coefficient (c2) for rc building with shear walls
recently, scientists developed the seismic rehabilitation of structures and their points of view were changed from strength to the performance of structures. nonlinear static procedure (nsp) or pushover analysis is a new method that is chosen for its speed and simplicity in calculations. “seismic rehabilitation code” & fema356 considered this method. result of this analysis is a target displace...
متن کاملEquivalent Damping Ratios of Structures with Supplemental Viscous Dampers
The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 1997
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.62.55_1