Study of steel moment connection with and without reduced beam section

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pushover Analysis of Steel Seismic Resistant Frames with Reduced Web Section and Reduced Beam Section Connections

The widespread brittle failure of welded beam-to-column connections caused by the 1994 Northridge and 1995 Kobe earthquakes highlighted the need for retrofitting measures effective in reducing the strength demand imposed on connections under cyclic loading. Researchers presented the reduced beam section (RBS) as a viable option to create a weak zone away from the connection, aiding the preventi...

متن کامل

Evaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)

The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...

متن کامل

Seismic behavior of drilled beam section in moment connections

Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...

متن کامل

Damage Avoidance Design Steel Beam-Column Moment Connection Using High-Force-To-Volume Dissipators

Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beamcolumn...

متن کامل

Numerical study of slotted web drilled flange moment frame connection

Beam connections with reduced drilled section and slotted web have been presented after the Northridge earthquake (1994). Their new geometrical shapes have been resulted in weakening of beams and subsequently the bette rperformance of connections in the earthquakes. In this research, the advantages of both connections, mentioned above, have been studied in the Slotted Web Drilled Flange (SWDF) ...